OT Program Mode Command

Properties


name
OT Program Mode Command
definition
Command that places the controller in a mode capable of reprogramming logic. This may or may not stop the program.
comment
BACnet: deviceCommunicationControl BACnet: reinitializeDevice
comment
GE-SRTP: SET PLC (RUN VS STOP)
see also
https://icscsi.org/library/Documents/ICS_Protocols/Control%20Microsystems%20-%20DNP3%20User%20and%20Reference%20Manual.pdf
see also
https://modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf
see also
https://nvlpubs.nist.gov/nistpubs/TechnicalNotes/NIST.TN.2023.pdf

Neighbors


Inferred Relationships

This page is experimental and may change significantly in future releases.

Hierarchy

(filtered)

Related Countermeasure Techniques

No related defensive techniques in this release.

Related Weaknesses

Related Offensive Techniques

No related offensive techniques in this release.